1. Technology overview
Kanden Energy Solution Co., Inc. (Kenes) is a Kansai Electric Power group company headquartered in Nakanoshima, Osaka, established in April 2001, providing utility and energy services to buildings and factories. Omaka Save-Air Central is its HVAC control service for central air-conditioning, designed to cut energy cost and CO2 without manual operation.
The service issues optimised operating commands automatically. The air-cooled heat pump chiller version adjusts chilled-water supply temperature by thermal load, and the combined version uses AI load forecasting from operating history and weather to split load between central and individual units. Save-Pro extends the approach to utility equipment generally, with a web dashboard and retrofit installation.
2. Highlighted features & specifications
- Automatic setpoint control: Chilled-water supply temperature is adjusted by thermal load.
- AI load forecasting: Load is predicted from operating history and weather to share load between systems.
- Demand control: Chiller output is reduced in stages to cap peak demand.
- Web dashboard: Savings and settings are shown in real time with downloadable data.
- Retrofit install: Sensors and control panels are added to existing equipment.
- Reports: Daily, monthly and annual analysis reports, with optional VPN remote monitoring.
3. Potential application
Office towers and hotels in Vietnam with air-cooled chillers could retrofit automatic supply-temperature control to reduce power bills. Hospitals and malls with combined central and individual air conditioning could balance loads using forecasting.
4. Benefits
The chiller version reports about 10 percent lower air-conditioning energy use while keeping indoor comfort. Initial cost is zero yen, with a service fee lower than the electricity savings under a standard five-year contract. Installation takes about two to three days with sensors and panels added and no change to existing systems. Savings vary by facility.
5. Market trends & opportunities
Building owners are under pressure to meet ZEB and decarbonisation targets, and HVAC is a large share of building energy use. Zero-upfront, savings-funded service models lower the barrier to retrofit. Vietnam's commercial buildings and hotels face rising power costs with similar central chiller systems.
6. Other information
Kanden Energy Solution Co., Inc., Nakanoshima Festival Tower, 2-3-18 Nakanoshima, Kita-ku, Osaka; established April 2001; Kansai Electric Power group. Reference customer on the page: Kanden Fudosan Shibuya Building.
One platform connecting startups, corporations, research institutions, regions and investors











Playbook & Handbook · February 6, 2026
Winning Accelerator Playbook 2026 by BambuUP
RETAIL E-COMMERCE: AI AND REAL-TIME DATA ARE TRANSFORMING HOW RETAIL BUSINESSES OPERATE